1. & 2. Best is overlap, although for many this is not a convenient or aesthetic option. Without overlap, some rising effluent will be missed and either deposit grease and moisture somewhere (as well as spread odor) or will hang in the air until the ventilation slowly removes it. With excess CFM, one may argue that there is an "aura" of air flow around a given aperture that effectively extends its size. This aura will be small, but might reach 3 inches. However, given baffles that had, say, an inch of water column pressure loss at 90 ft/min, and hence a big part of the 1.5X factor (with good MUA) for choosing the blower rated flow rate, if the flow through the baffles were significantly increased the pressure loss would also increase (not necessarily linearly) so the point on the fan curve would change, partly negating the excess flow.
In other words, whereas an 1100 CFM blower might yield 700 cfm when used with an 8 sq. ft. baffled aperture, reasonable MUA, ducting, etc., with a 6 sq. ft. baffled aperture it might only move 600 CFM. Still more than the 540 recommended for six square feet, but not overkill. Assuming a continuous blower control (300 - 1100 say), you can just not turn it all the way to full speed.
Now, as the real aperture dimensions start getting smaller and smaller due to cabinet factors and dimensions of standardized inserts, turning down the blower may also prove useful just for reduced baffle turbulence noise that the silencer cannot help.
Your contractor may be fazed by the MUA when he finds out that it needs to be separate from the furnace system for a variety of reasons that jwvideo spelled out in a recent thread. Sorry I don't recall the thread name. Best is to have the furnace have its own MUA to avoid backdrafting. Ditto hot water heater if separate. Or use a mechanical room to house such stuff with its own MUA and closed path to the kitchen.
3. & 5. The most important reason for an external blower in my view is the ability in some cases to fit a silencer in the duct path. This is the most useful addition to the ventilation if one likes to chat while cooking. Typically, this requires an attic space and a roof blower, but some duct schemes (through garages, for example) may allow room for a silencer in a below kitchen ceiling horizontal path, or potentially one could be used in an external chase rising to a top-mounted blower. Note that a Fantech 10-inch silencer is about 14 inches in diameter.
External blowers like the Abbaka and similar shaped Broan and Wolf blowers are typical because they have low profiles and blow down the roof. Commercial up-blast designs can also be used, and may have advantages depending on types and depths of snow. (I have a Wolf/Broan 1500 CFM unit.)
If you want to use Abbaka, for example, but buy an ModernAire liner, for example, then ModernAire needs to know that they have to provide a control, or space for a control, compatible with the Abbaka blower. I think Abbaka, Broan (and hence Wolf) blowers are all induction motors, so appropriately sized triac/diac or more sophisticated semiconductor continuous controls should work. I think I could rip of my Wolf (Broan) blower and substitute an Abbaka and use the Wolf hood (actually made by Independent) triac/diac motor control with it.
These blowers are not too noisy on the roof relative to nearby areas, but can be heard. For consideration of mounting on the side of a house: one would have to ask, are you in Londonderry, NH where the lots are 2 acres, or in a suburb of San Francisco, CA where 2 meters separates the house from the property line.
4. I have no information or experience about Miele liners. I only have a Miele dishwasher.
I don't have a ModernAire ventilation hood either. Their name comes up because they are known to build custom hoods that many are pleased with. They are not the only such source however, so serious trolling of the Internet may be useful. I found in my reno it useful to buy everything early so I could carefully measure details that are hard to otherwise determine that influence the cabinetry and outlet locations. However [prime caveat], your warranty may start when you take delivery (Wolf is rather generous on this point) and in at least one claim raised here, Modernaire would not correct a problem after many months of the liner not being opened and inspected (as I recall). So, try to avoid taking a few years to finish your reno.
Also, on that point, you may find it helpful to make lower cabinets deeper than standard to more easily fit plumbing, electrical, refrigerator depths, etc. It just costs a little more to do so.
If I forgot to answer something, don't be shy about bringing it to my attention.
kas